HP StorageWorks Fabric OS 5.X Command Reference Guide (AA-RVHVB-TE, September 2005)

Table Of Contents
Fabric OS 5.x command reference guide 631
Disables a blade slot.
Synopsis
slotoff slotnumber
Availability
admin
Description
Use this command to disable a nonfaulty blade unit while leaving the blade unit powered on.
This command disables both the external and internal ports on the blade, in contrast to the
bladeDisable command, which only disables external ports. Unlike ports affected by
bladeDisable, ports on a slot disabled by this command are not re-enabled after switchEnable,
switchStart, or switchReboot.
Operands
This command has the following operand:
Examples
To power off blade unit 3:
See also
bladeDisable
slotOn
slotShow
slotOff
slotnumber Specify the slot number of the blade to disable. This operand is
required.
switch:admin> slotoff 3
Slot 3 is being disabled.