HP StorageWorks Core Switch 2/64 Getting Started & General Reference Guide
Specifications 73
Environmental
The following table lists the acceptable environmental ranges. The
requirements for non-operating conditions are also provided for acceptable
storage and transportation environments.
Table 13. Environmental Requirements
Condition Acceptable Range
Temperature (operating)
*
*The 0-40°C temperature range is for the chassis. Individual components
may have a higher range. For example, the 16-port cards and CP cards have
a temperature range up to 75°C. Use the tempShow or Fabric Watch
commands to show temperature status of all components.
0°C to 40°C
(32°F to 104°F)
Temperature (non-operating) -35°C to 65°C
(-31°F to 149°F)
Humidity (operating) 5% to 85% RH non-condensing, at 40°C
Humidity (non-operating) 0% to 90% RH non-condensing, at 40°C
Altitude (operating) 0 to 3 km above sea level
(1 to 10,000 ft. altitude)
Altitude (non-operating) 0 to 12 km above sea level
(1 to 39,370 ft. altitude)
Shock (operating) 4 G, 11 MS duration, half-sine wave
Shock (non-operating) 20 G, 11 MS duration, sq. wave
Vibration (operating) 5 G, 0-3 kHz at 1.0 octave/minute
Vibration (non-operating) 10 G, 0-5 kHz at 1.0 octave/minute
Heat Dissipation 64 ports: 3690 BTU/hr.
128 ports: 6700 BTU/hr.