HP StorageWorks Core Switch 2/64 Getting Started & General Reference Guide
56 getting started and general reference guide
Table 5. 16-Port Card LED Patterns
Location of
LED
Purpose
of LED
Color of LED Status of Hardware Recommended Action
Top LED Power No light
(LED is off)
16-port card does not have
incoming power.
Ensure card is firmly seated
and has power.
Steady green 16-port card has incoming
power.
No action required.
Second LED Status No light
(LED is off)
16-port card is either
healthy or does not have
power.
Verify Power LED is lit.
Steady yellow 16-port card is faulty Ensure card is firmly seated
and check status with
slotShow command. If
LED is still yellow, consult
HP support.
Slow-flashing
yellow:
on 2 second;
off 2 second
16-port card is not seated
correctly, or is faulty.
If light continues to flash,
pull card out and reseat. If
LED continues to flash,
replace card.
Fast-flashing
yellow:
on 1/2 second;
off 1/2 second
Environmental range
exceeded.
Check for out-of-bounds
environmental condition.
Left of each
port, upper
LED
Port
Speed
No light
(LED is off)
Port is either set to 1 Gbps
mode or does not have
incoming power.
Verify Power LED is lit.
To change the mode, refer
to the hp StorageWorks
fabric os procedures guide.
Steady green Port is set to 2 Gbps. No action required.
!