HP StorageWorks Audit Log reference guide (5697-5923, June 2006)

Remote Control Unit (RCU) Function122
[RCU]
Remote Control Unit function
Change RCU Option
Change Remote Control Unit Option operation
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of the log entry (000000 to 999999)
Detailed Information
Detailed information for this operation is shown in Table 79.
Table 79 Detailed Information for Change RCU Option
user-name,xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,[RCU],Change RCU Option,,Normal
end,Seq.=xxxxx
+{S/N,SSID,Controller ID,Min. Path,MIH Time(s), Round Trip
Time(ms),Incident,FREEZE}={99999,0x0004,
4,08,015,001,only to RCU host,Disable}
Item Description
S/N Indicates a serial number of the RCU device where the RCU option setting is changed.
Path Gr. ID The RCU path group ID where the RCU optional setting is changed. When the path
group ID is default setting, "Default" is output.
Controller ID The controller ID of the RCU where the optional setting is changed.
SSID Indicates SSID of the RCU where the optional setting is changed.
Min. Path The minimum number of paths after change.
MIH Time(s) The value of RIO MIH (Remote I/O Missing Interrupt Handler) timer (wait time until data
copy from MCU to RCU is completed). The unit represents seconds.
Round Trip Time(ms) The round-trip response time (delay time for round-trip remote I/O) after change. The unit
is in milliseconds. This value is output when Continuous Access XP or TrueCopy for z/OS
is used.
Incident The incident of RCU after change. This value is output only when TrueCopy for z/OS is
used.
"only to RCU host " or " to any host " is output.