Hitachi TrueCopy (TM) for Mainframe User Guide: HP XP24000 Disk Array, HP XP20000 Disk Array (T5211-96014, May 2011)
Table 12 HP Business Continuity Manager Commands Corresponding to PPRC Commands (continued)
Support typeBusiness Continuity Manager
commands
ParameterPPRC commands
configYKFREEZE/YKRUNDEVNCGROUP
configPRIM
configSEC
CommandFREEZE/RUN
configYKDELPTHDEVNCDELPATH
configPRIM
configSEC
*1
The YKSUSPEND command supports only the pair suspend command for M-VOL.
*2
For further information for parameter, see “Supporting Condition of PPRC
Command Parameter” (page 41).
Table 13 Supporting Condition of PPRC Command Parameter
Business Continuity Manager supportParameterPPRC command
config
(X is not supported.)
AgnnXCESTPAIR
Not supportedAvnnX
DRAIN operandAGD00CSUSPEND
PURGE operandAGP00
Not supportedAVD00
Not supportedAVP00
configAG000CDELPAIR
Not supportedAV000
Not supportedAC000CRECOVER
configAG000
Not supportedAV000
Table 14 SAID Values for the PATH LINK Parameter (= ports) (FRONT CL1)
1
SAIDPortPackage
Location
SAIDPortPackage
Location
SAIDPortPackage
Location
SAIDPortPackage
Location
X'0084'CL9-E1BU
3
X'008C'CL9-N1KUX'0008'CL1-J1GUX'0000'CL1-A1EU
2
X'00A4'CLB-E(Add14)X'00AC'CLB-N(Add10)X'0028'CL3-J(Add4)X'0020'CL3-A(Basic)
X'00C4'CLD-EX'00CC'CLD-NX'0048'CL5-JX'0040'CL5-A
X'00E4'CLF-EX'00EC'CLF-NX'0068'CL7-JX'0060'CL7-A
X'0085'CL9-FX'008D'CL9-PX'0009'CL1-KX'0001'CL1-B
X'00A5'CLB-FX'00AD'CLB-PX'0029'CL3-KX'0021'CL3-B
X'00C5'CLD-FX'00CD'CLD-PX'0049'CL5-KX'0041'CL5-B
Business Continuity Manager Support 41