Hitachi TrueCopy for IBM z/OS User and Reference Guide (T5211-96001, June 2007)
4-28 Using TrueCopy for z/OS GUI
Hitachi Universal Storage Platform V TrueCopy for IBM z/OS User’s Guide
System Option Window
The System Option window (see Figure 4-13) allows you to clear the
TrueCopy for z/OS remote copy SIMs and to change the option settings of the
storage system and CUs.
Figure 4-13 System Option Window
• The Clear SIM button: allows you to clear all remote copy SIMs (service
information messages) from the connected storage system.
• Tree: displays Option at the top of the tree. Subsystem Option and CU
Option will be displayed below Option. CU Option will be displayed for each
LDKC.
• List: displays nothing by default. When you select Subsystem Option or
CU Option, the option settings will be displayed.
• Preview List: displays the settings before you click the Apply button for
changing or deleting the settings. To change or delete settings, right-click the
preview list.
• Operation: displays the status of the process in progress. The following
status of operation is displayed:
– No Operation