HP StorageWorks XP24000 Continuous Access Software User and Reference Guide, v01 (T5278-96002, June 2007)

1C 2C
1D
2E
Switch
: FL-Port Connection
: Fibre Channel
Interface Port
Switch
Switch
Switch
2D
SSID: 0244
SSID: 0088
Serial #: 05033
Serial #: 05031
MCU
RCU
Add RCU (Fibre)
RCU S# = 05031, SSID = 0088, No. of Paths = 3
For path 1: MCU Port = 1E, RCU Port = 2D, Logical Adr = 00
For path 2: MCU Port = 1E, RCU Port = 2E, Logical Adr = 00
For path 3: MCU Port = 5E, RCU Port = 1D, Logical Adr = 00
Figure 27 Add RCU Operation Fibre-Channel Interface
Changing the RCU Options
The RCU Option dialog box (see Figure 28 on page 76) a llows you to set the RCU options for the
connected MCU. The RCU options apply to all MCU CUs and to all RCUs connected to the MCU.
The RCU O ption dialog box is presented during the add RCU process, and can also be opened by
right-clicking on the RCUs and clicking the RCU OperationÆChange RCU Option command.
XP24000ContinuousAccessSoftwareUserand ReferenceGuide
75