HP StorageWorks XP24000 Continuous Access Software User and Reference Guide, v01 (T5278-96002, June 2007)

for Mainframe, and TrueCopy Asynchronous for Mainframe) can share the same remote copy
connections.
Remote Copy Con
nections
Figure 8 on page 47 shows the remote copy connection congurations for Fibre Channel interface
Continuous Access operations. The MCU and RCU of ea ch Continuous Access pair must be c onnected
via multimode
shortwave or single-mode longwave optical brecables. If youuse multimodeshortwave
optical bre c
ables, bre cables up to 1.5 km in length and up to two switches are required for distances
greater than
0.5 km. If you use single-mode longwave optical bre cables, bre c ables up to 30 km
in
length an
d
up to two switches are require d for distances greater than 10 km. Continuous Access
operations
can
be performed at distances of up to 30 km (18.6 miles) using standard single-mode
longwave support. Long-distance solutions are provided using approved channel extenders and
communication lines.
Shortwave: 0.5 km
Longwave: 10 km
Unrestricted distance
MCU/RCU
RCU/MCU
MCU/RCU
RCU/MCU
MCU/RCU
RCU/MCU
MCU/RCU RCU/MCU
MCU/RCU
RCU/MCU
Shortwave: 1.5 km
Longwave: 30 km (Max)
Multimode shortwave optical fibre cables
up to 0.5 km
Single-mode longwave optical fibre cables
up to 10 km
Switch
Channel Extender
A
TM telecommunications lines
Figure 8
Remote Copy Connection Congurations
Note:
F
or
Fibre Channel interface connections, you can use the same switches as for ordinary switch
connections, and no special settings are required for the storage systems.
A Fibre Channel interface connection provides three different con gurations (see HP StorageWorks
XP24000 LUN Manager User’s Guide):
Direc
tconnection (see Figure 9 on pag e 48): Two devices are connected directly together.
Switch connection (see Figure 10 on page 48): Up to three optical bre cables are connected
together via the switches to connect the devices. Up to two switches can be used.
Exte
nder connec tion (see Figure 11 on page 49): Channel extenders and switches are used to
connect the devices across large distances.
XP24000ContinuousAccessSoftwareUserand ReferenceGuide
47