HP StorageWorks XP24000 Continuous Access Journal Software User and Reference Guide, v01 (T5278-96001, June 2007)

Cancel: Cancels the settings you m ade on the Add D KC window and then closes the window.
Changing Optio
ns
for Logical Paths and Storage Systems
The DK C Option window (see Figure 51 on page 101) allows you to set the logical path options and
storage system options. These options will apply to the local storage system and the corresponding
remote storage
system.
Note:
DKC is an
acronym for d
isk controller, which controls an entire storage system. Continuous Access
Journal windows use the word DKC to indicate a storage system.
To change logical path options and storage system options, follow the procedure below. Not only the
primary storage system administrator but also the secondary storage system administrator can per form
this
operation.
1. Ensure that t
he
Remote Web Console main window is in Modify mode.
For detailed information about how to do this, see HP StorageWorks XP24000 Remote Web
Console User’s Guide.
2.
Ensure that the DKC Operation window is displayed (see DKC Operation Window on page 85).
3. In Display,select DKC.
4. Select LDKC
from the tree.
The list displays a list of remote storage systems.
5. From the list, select and right-click the d esired remote storage system.
6. From the po
p-up menu, select DKC Operation and Change DKC Option.
The DKC Option window appears (Figure 51 on page 101).
7. On the D KC Option window, change the options as desired. For detailed information about the
options, see the explanations below Figure 51 on page 101.
8. Select Set
to close the DKC Option window.
9. See the Preview list to check the settings that you have made.
To mo d ify a setting, select and right-click the setting from the Preview list and then select
Modify. A window appears and allows you to modify the setting.
•To cancel
a
setting, select and right-click the setting in the Preview list and then select Cancel.
10. Select Apply to apply the settings that you have made.
Note
: If an error occurs, the right-most column of the Preview list displays the error code. To
view detailed information about the error, right-click the error code and then select Error Detail.
An error message appears and gives you detailed information about the error.
Figure 51 DKC Option Win dow
The DKC Option window displays the following:
The Minimum Paths option species the minimum number of paths required for ea ch remote
storage system connected to the local storage system (default value is 1).
Note:
You cannot change the Minimum Paths for the current version.
XP24000 Continuous Access Journal Software User a nd Reference Guide
101