Hitachi TrueCopy for IBM z/OS User and Reference Guide (T5211-96001, June 2007)

3-2 Preparing for TrueCopy for z/OS Operations
Hitachi Universal Storage Platform V TrueCopy for IBM z/OS User’s Guide
System Requirements
TrueCopy for z/OS operations involve the USP V MCUs and RCUs containing
the main and remote volumes, the remote copy connections between the
MCUs and RCUs, the zSeries
®
and S/390 host(s) at the main and remote sites,
and the TrueCopy for z/OS software. The TrueCopy for z/OS system
requirements are:
MCU: USP V storage system with TrueCopy for z/OS installed by using
license code. Note: For information on remote copy operations using the
TagmaStore USP/NSC storage system as an MCU, please refer to the Hitachi
TagmaStore USP/NSC TrueCopy for z/OS User and Reference Guide
(MK-94RD214).
Note: For important information about proper configuration for your
operational environment, refer to Appendix C.
RCU: USP V storage system with TrueCopy for z/OS installed by using
license code. Note: TagmaStore USP/NSC storage system with TrueCopy for
z/OS installed can be used as an RCU connected to a USP V MCU. For
assistance with mixed storage system configurations, please contact your
Hitachi representative.
Note: TrueCopy for z/OS can coexist with TrueCopy (all copy modes) in
the same USP V storage system. Full fibre-channel support will allow
concurrent fibre-mode TrueCopy and TCz operations.
Note: The USP V storage systems may have additional installation
requirements (e.g., system option modes, DKC-F510I-32FS2, DKC-F515I-
MIX2, additional cache, etc.). For information on system option modes for
TrueCopy for z/OS, refer to Table 2-2.
zSeries and S/390 host: MVS/DFP 3.2.0 + PTF, or VM/ESA
®
2.1.0 + PTF.
Optional error recover procedure (ERP) functions require MVS/DFP 3.2.0
or later.
ICKDSF R16 + PTF functions require VM/ESA 2.1.0 or later.
If the primary and/or secondary system consists of several CPU
complexes, a SYSPLEX timer is required to provide a common time
reference for the host I/O time-stamping function.
Remote copy connections – fibre channel:
Multimode or single-mode optical fibre cables are required at both the
MCU and RCU.
For distances from 0.5 km to 1.5 km (1,640 to 4,920 feet), multimode
shortwave fibre channel interface cables with up to two switches are
required.
For distances from 10 km to 30 km (6.2 to 18.6 miles), single-mode
longwave fibre channel interface cables with up to two switches are
required.