Hitachi TrueCopy for IBM z/OS User and Reference Guide (T5211-96001, June 2007)

Performing TrueCopy for z/OS Pair Operations 6-17
Hitachi Universal Storage Platform V TrueCopy for IBM z/OS User’s Guide
M-VOL and R-VOL:
LDKC number, CU number, and device ID
Device emulation type
Capacity (number of cylinders)
Note: If "#" is added to the end of the device ID (i.e. 00:00:3F#), the LDEV
that the LDEV number indicates is an external volume. For details on an
external volume, please refer to the Universal Volume Manager User's Guide.
CLPR: The CLPR number and the CLPR name of the volume on the primary
site are displayed.
Pair Status: Current TCz pair status of the selected volume: simplex,
pending, duplex, or suspend, suspending, deleting. If the pair status is
suspended, the suspend type and consistency status (TCzA only) are also
displayed.
Pair Synchronized: For pending duplex pairs, this value indicates the
percent completion of the initial copy operation. For duplex TCz Synchronous
pairs, this value is always 100% after the initial copy operation is complete.
For TCzA pairs:
For a duplex TCzA pair, this value indicates the number of cylinders/tracks
(% of total) that are marked as modified in the bitmap for resynchronization.
The total number of cylinders/tracks = the number of M-VOL cylinders/tracks
(since the R-VOL can be larger than the M-VOL).
For a suspended TCzA R-VOL, this value indicates the number of
cylinders/tracks (% of total) containing recordsets lost at the RCU (reached
the RCU but not settled before suspension).
For a suspended TCzA M-VOL, this value indicates the number of
cylinders/tracks (% of total) which contain:
Tracks that have not yet been copied by the initial copy or resync copy
operation (this applies only when suspended during initial copy or during
resync copy)
Records updated by the primary system after suspension
Recordsets lost at the MCU (created but not sent to the RCU before
suspension)
Recordsets lost at the RCU (if the MCU can get this information from the
RCU).
RCU S/N and SSID: S/N and SSID of the RCU (or MCU if connected to the
RCU).
Controller ID: allows you to select the controller ID of the RCU. The
controller ID for USP V is 5, the controller ID for TagmaStore USP/NSC is 4,
and the controller ID for 9900V is 3. The model name is displayed next to the
controller ID.