HP StorageWorks Continuous Access EVA Administrator Guide (T3687-96043, December 2005)
and activate them. However, you must manually mount each individual NSS volume by entering
MOUNT VolumeName at the NetWare console.
• If the remote hosts are already up and running, or if they do not recognize the drives, issue the
following command from the console before mounting the volumes:
SCAN FOR NEW DEVICES
Alternatively, you can use the NWCONFIG utility to issue this same command.
Next, mount the volumes with the following commands:
MOUNT ALL (for traditional NetWare volumes)
MOUNT VolumeName (for NSS logical volumes)
Sun Solaris procedure to resume I/O
• Reboot the remote hosts using the reboot –– –r command, or use the following
version–dependent commands to update the Secure Path Manager:
• Solaris 6, 7, a
nd 8–
drvconfig –v
disks
/opt/CPQswsp
/bin/spmgr display
• Solaris 9–
• Present new units with LUN numbers sequentially following the old LUNs.
•Runthefollo
wing commands:
devfsadm –C
If you are using Secure Path:
/opt/CPQsws
p/bin/spmgr display
• If Secure Path was not configured for these units, use the following version–dependent commands
to add them to the Secure Path Manager.
•Solaris2.6,
7, a n d 8 –
/opt/CPQswsp/bin/spconfig
/opt/CPQswsp/bin/spmgr/display –u
/opt/CPQsws
p/bin/spmgr add <WWLUNID>
devfsadm –C
/opt/CPQswsp/bin/spmgr display
•Solaris9–
• Add the units with spmgr add <WWLUNID> or spmgr add–r WWNN all.
•Runupdate_drv –f sd to inform the system about attribute changes to the sd driver .
•Rundevfsad
m–Cto create /dev entries for the new units.
• If you are using the mpio, and it has not been configured for these devices, issue the following
commands to configure the new devices:
• Use the following cfgadm command as follows to list of the paths to the LUNS.
# cfgadm –a
l –o show_FCP_dev
Output:
c3 fc-private connected unconfigured unknown
c3::210000
e08b0a5b65 unknown connected unconfigured unknown
c3::500060e802eb2b0b,0 disk connected unconfigured unknown
c4 fc-private connected unconfigured unknown
c4::210100
e08b2a5b65 unknown connected unconfigured unknown
c4::500060e802eb2b14,0 disk connected unconfigured unknown
•Thecfgadm comma nd is used to configure the controller instances for mpxio control. Run
this comma nd for each EVA port on the storage array.
HP StorageWorks Continuous Access EVA administrator guide