HP StorageWorks Command View SDM Installation and User Guide (T1086-96023, February 2005)

32 Installing Command View SDM
Installation Tips
For the latest information on installing and upgrading the software,
refer to the README file on the Command View SDM Installation CD.
The README is located in the corresponding operating system
directory.
When upgrading to a newer version of Command View SDM, always
remove the previous version before installing the new software.
Make sure EMS hardware monitoring is installed and operating on the
host before installing Command View SDM. This will ensure that the
array is automatically added to the EMS configuration and array
events will be detected and reported.
Installation Steps
1 Log onto the system as root or superuser.
2 If upgrading to a newer version of Command View SDM, save any
configuration files and remove the old software. See the following section.
3 Insert the Command View SDM software CD into the CD-ROM drive.
4 Identify the device file for the CD-ROM:
ioscan -funC disk
eg: disk 2 8/16/5.2.0 sdisk CLAIMED DEVICE TOSHIBA
CD-ROM XM-5701TA
/dev/dsk/c2t2d0 /dev/rdsk/c2t2d0
5 Create a mount point directory. For example:
mkdir /cdrom
Use a directory that does not exist
6 Execute ps -ef |grep pfs command, to confirm if the following processes
are running
root 2588 2587 0 15:31:18 pts/tb 0:00 pfsd.rpc
root 2586 2585 0 15:31:00 pts/tb 0:00 pfs_mountd.rpc
root 2587 2579 0 15:31:18 pts/tb 0:00 /usr/sbin/pfsd
root 2585 2579 0 15:31:00 pts/tb 0:00 /usr/sbin/
pfs_mountd