HP StorageWorks Command View SDM Installation and User Guide (T1086-96023, February 2005)

100 Command Line User Interface
FRU Identifiers
All the Field Replaceable Units (FRUs) within the array are identified using a
FRU location identifier, <FRULocation>. The FRU location identifier
specifies the component to which a command is directed. It has the format:
<enclosure>/[component].[subcomponent]
The values for the elements of the FRU location identifier are listed in Table 11.
Example
The following command identifies the disk in slot 5 of disk enclosure 2 on FC
loop 1 on the array identified by alias Array1.
Table 11 FRU Location Identifier Values
Element Values
<enclosure> M: main array enclosure
JA0 - JA5: Disk enclosures 0 through 5 on back-end FC loop 1. The number corresponds to
switch setting on the disk enclosure. On the VA 7400/7110, all disk enclosures are on loop
1.
JB0 - JB5: Disk enclosures 0 through 5 on back-end FC loop 2. The number corresponds to
switch setting on the disk enclosure. Only the VA 7410 has a FC loop 2.
<component> D1 - D15: disk modules in slots 1 through 15
C1 - C2: controller/LCC modules in slots
*
1 or 2
P1 - P2: power supply/fan modules in slots
*
1 or 2
MP1: midplane assembly
<subcomponent> B1: battery located on controller
M1: DIMM in socket 1
H1 - H2: host ports 1 and 2 (port 2 on VA 7410 only)
J1 - J2: Disk enclosure ports 1 and 2 (port 2 on VA 7410 only)
PM1: processer
G1 - G2: GBIC in slot 1or 2
* 1 is the left slot; 2 is the right slot, as viewed from the rear of the array
armcfg -D JA2/D5 -a Array1
Identifies disk 5 in disk enclosure 2
Identifies array with alias Array1
on FC loo
p
1