4.1.0 HP PolyServe Matrix Server administration guide (T5392-96073, October 2010)

If you want to reverse this order, preface the Stop script with the prefix [post] on
the Scripts tab.
Event severity
If a Start or Stop script fails or times out, a monitor event is created on the node
where the failure or timeout occurred. Configuration errors can also cause this
behavior. You can view these events on the PolyServe Management Console and
clear them from the Console or command line after you have fixed the problems that
caused them.
When an event is created, the ClusterPulse process may initiate failover of the
associated virtual host. You can configure the failover behavior with the Event Severity
attribute. There are two settings: CONSIDER and IGNORE.
CONSIDER. This is the default value. Events are considered when Matrix Server makes
failover decisions.
IGNORE. Events are ignored and Start or Stop script failures will not cause failover.
This is useful when the action performed by the Start and Stop scripts is not critical,
but is important enough that you want to keep a record of it.
To configure event severity from the command line, use this option:
--scriptSeverity consider|ignore
Script ordering
Script ordering determines the order in which Matrix Server runs Start and Stop
scripts when a shared device or virtual host moves from one server to another. If you
do not configure a monitor with Start and Stop scripts, the script ordering configuration
has no effect.
There are two settings for script ordering: SERIAL and PARALLEL.
SERIAL. This is the default setting. When a shared device or virtual host moves from
one server to another, Matrix Server enforces the following strict ordering sequence
for running Start and Stop scripts.
1. The Stop script is run on all servers where the shared device or virtual host should
be inactive.
2. Matrix Server waits for all Stop scripts to complete.
3. The Start script is run on the server where the virtual host or shared device is
becoming active.
Configure device monitors228