4.0.0 HP Polyserve Matrix Server Event Notification Guide (T5392-96053, March 2010)

Message and Corrective ActionID
Probe failed: <IP address> Unable to open SNMP session.
The monitor probe failed on the specified server. The server may no longer be
suitable for the virtual host associated with the monitor. If the virtual host was active
on the affected server, it may have failed over to another server. (Whether failover
occurs is dependent on the configuration of the monitor and the virtual host.)
Action. Verify that the monitor is configured correctly. Check the server and the
network interface associated with the virtual host for problems.
4566
SNMP session error resolved.
Action. None. Alert 4566 is resolved.
4567
Probe failed: <IP address> Returned OID value is missing or invalid.
The monitor probe failed on the specified server. The server may no longer be
suitable for the virtual host associated with the monitor. If the virtual host was active
on the affected server, it may have failed over to another server. (Whether failover
occurs is dependent on the configuration of the monitor and the virtual host.)
Action. Verify that the monitor is configured correctly. Check the server and the
network interface associated with the virtual host for problems.
4568
SNMP OID return value error is resolved.
Action. None. Alert 4568 is resolved.
4569
Probe failed: <IP address> SNMP Get request failed.
The monitor probe failed on the specified server. The server may no longer be
suitable for the virtual host associated with the monitor. If the virtual host was active
on the affected server, it may have failed over to another server. (Whether failover
occurs is dependent on the configuration of the monitor and the virtual host.)
Action. Verify that the monitor is configured correctly. Check the server and the
network interface associated with the virtual host for problems.
4570
SNMP Get request error is resolved.
Action. None. Alert 4570 is resolved.
4571
Probe failed: <IP address> SNMP Get request timed out.
The monitor probe failed on the specified server. The server may no longer be
suitable for the virtual host associated with the monitor. If the virtual host was active
on the affected server, it may have failed over to another server. (Whether failover
occurs is dependent on the configuration of the monitor and the virtual host.)
Action. Verify that the monitor is configured correctly. Check the server and the
network interface associated with the virtual host for problems.
4572
Event messages20