4.0.0 HP Polyserve Matrix Server Administration Guide (T5392-96052, March 2010)

This option is useful when integrating Matrix Server with a custom application where
certain application-specific actions must be taken before failback can occur.
For more information on the interaction between the Probe Severity attribute and the
virtual host failback policy, see Virtual hosts and failover protection on page 23.
To set the Probe Severity from the command line, use this option:
--probeSeverity nofailover|autorecover|noautorecover
Custom scripts
The Scripts tab lets you configure custom Recovery, Start, and Stop scripts for a device
monitor.
Device monitors can optionally be configured with scripts that are run at various
points during cluster operation. The script types are as follows:
Recovery script. Runs after a monitor probe failure is detected, in an attempt to restore
the device.
Start script. Runs as a device is becoming active on a server.
Stop script. Runs as a device is becoming inactive on a server.
Configure device monitors226