3.7.0 HP StorageWorks HP Scalable NAS File Serving Software event notification guide HP Scalable NAS for Linux (AG513-96007, June 2009)

Message and Corrective ActionID
Evicted device issue resolved
Action. None. Alert 51100 is resolved.
51101
These export paths (<percent> total) are not mounted on a PSFS filesystem
Action. If you intended to export a PSFS filesystem, double-check the exported
pathname. If the pathname is correct, ensure that FS Option for Linux started
successfully. If one or more server nodes failed to join the cluster and mount all
configured filesystems, execute /etc/init.d/pmxs start on the affected nodes.
If that does not resolve the problem, contact Technical Support.
51102
Export paths issue resolved
Action. None. Alert 51102 is resolved.
51103
Unable to obtain vNFS HA data (mxds failed to open value <value>)
Unable to obtain Virtual NFS Server HA data because a mxds key could not be
opened.
51106
vNFS HA data (mxds value) issue resolved
Action. None. Alert 51106 is resolved.
51107
Out of memory
Action. The system could not allocate memory. This may be a transient condition.
51108
Out of memory issue resolved
Action. None. Alert 51108 is resolved.
51109
Unknown RPC service: <service>
Action. Ensure that the NFS services have been started.
51110
Unknown RPC service issue resolved
Action. None. Alert 51110 is resolved.
51111
inet_aton() failed for localhost
Action. The system could not resolve "localhost" to an IP address. Check your IP
name resolution configuration.
51112
inet_aton() failed for localhost issue resolved
Action. None. Alert 51112 is resolved.
51113
HP Scalable NAS File Serving Software event notification guide 41