3.7.0 HP StorageWorks HP Scalable NAS File Serving Software event notification guide HP Scalable NAS for Linux (AG513-96007, June 2009)

Message and Corrective ActionID
Probe failed: <IP address>. NIS service is not available via tcp or udp.
The monitor probe failed on the specified server. The server may no longer be
suitable for the virtual host associated with the monitor. If the virtual host was active
on the affected server, it may have failed over to another server. (Whether failover
occurs is dependent on the configuration of the monitor and the virtual host.)
Action. Verify that the monitor is configured correctly. Check the server and the
network interface associated with the virtual host for problems.
4602
NIS service access is resolved.
Action. None. Alert 4602 is resolved.
4603
Probe failed: <IP address> Socket operation requires a valid IP address.
The monitor probe failed on the specified server. The server may no longer be
suitable for the virtual host associated with the monitor. If the virtual host was active
on the affected server, it may have failed over to another server. (Whether failover
occurs is dependent on the configuration of the monitor and the virtual host.)
Action. Verify that the monitor is configured correctly. Check the server and the
network interface associated with the virtual host for problems.
4606
Invalid IP address resolved.
Action. None. Alert 4606 is resolved.
4607
Probe failed: <IP address> Unable to create socket.
The monitor probe failed on the specified server. The server may no longer be
suitable for the virtual host associated with the monitor. If the virtual host was active
on the affected server, it may have failed over to another server. (Whether failover
occurs is dependent on the configuration of the monitor and the virtual host.)
Action. Verify that the monitor is configured correctly. Check the server and the
network interface associated with the virtual host for problems.
4608
Socket creation resolved.
Action. None. Alert 4608 is resolved.
4609
Probe failed: <IP address> Unable to connect socket.
The monitor probe failed on the specified server. The server may no longer be
suitable for the virtual host associated with the monitor. If the virtual host was active
on the affected server, it may have failed over to another server. (Whether failover
occurs is dependent on the configuration of the monitor and the virtual host.)
Action. Verify that the monitor is configured correctly. Check the server and the
network interface associated with the virtual host for problems.
4610
Event messages26