3.7.0 HP StorageWorks HP Scalable NAS File Serving Software event notification guide HP Scalable NAS for Linux (AG513-96007, June 2009)

Message and Corrective ActionID
Probe failed: <monitor> Unsupported monitor type '<monitor>'.
The monitor probe failed on the specified server. The server may no longer be
suitable for the virtual host(s) associated with the monitor. If the virtual host(s) were
active on the affected server, they may have failed over to another server. (Whether
failover occurs is dependent on the configuration of the monitor and the virtual
host(s).)
Action. Verify that the monitor is configured correctly. Check the server and the
network interface associated with the virtual host(s) for problems.
4526
Unsupported monitor type resolved.
Action. None. Alert 4526 is resolved.
4527
Probe failed: <IP address> Monitor type '<monitor>' will terminate to load
newer function.
The monitor probe failed on the specified server. The server may no longer be
suitable for the virtual host associated with the monitor. If the virtual host was active
on the affected server, it may have failed over to another server. (Whether failover
occurs is dependent on the configuration of the monitor and the virtual host.)
Action. Verify that the monitor is configured correctly. Check the server and the
network interface associated with the virtual host for problems.
4528
Service monitor type reloaded.
Action. None. Alert 4528 is resolved.
4529
Probe failed: <monitor> Monitor type '<monitor>' will terminate to load
newer function.
The monitor probe failed on the specified server. The server may no longer be
suitable for the virtual host(s) associated with the monitor. If the virtual host(s) were
active on the affected server, they may have failed over to another server. (Whether
failover occurs is dependent on the configuration of the monitor and the virtual
host(s).)
Action. Verify that the monitor is configured correctly. Check the server and the
network interface associated with the virtual host(s) for problems.
4530
Device monitor type reloaded.
Action. None. Alert 4530 is resolved.
4531