3.7.0 HP StorageWorks HP Scalable NAS File Serving Software command reference guide HP Scalable NAS for Linux (AG513-96003, October 2009)
This command can be used only when the cluster is offline. Specify Multicast or
Unicast as appropriate.
santest—Test the switch configuration
mx config santest --santype [fc|iscsi] <switch> ...
This command can be used only when the cluster is offline. <santype> is either fc
for Fibre Channel or iscsi for iSCSI.
santype—Set the SAN storage type
mx config santype [fc|isci]
This command can be used only when the cluster is offline. Specify the appropriate
type, either fc for Fibre Channel or iscsi for iSCSI. The default is fc.
secret—Set the network secret license key
mx config secret <alphanumeric key>
This command can be used when the cluster is either online or offline. The key can
be anything you want.
testfencing—Test the fencing configuration
mx config testfencing <server> ...
This command can be used when the cluster is either online or offline.
webfencing—Configure the web-based fencing module
mx config webfencing --ruser <user name> --vendor <vendor>
--mixedvendor yes|no --hostname <name>|--hostsuffix <suffix>
|--ipdelta <delta> [--type reset|shutdown] [--bladeslot <slot>]
[--sharedlogin yes|no] [--rpassword <password>]
This command can be used only when the cluster is offline. The options are as follows.
Be sure to specify how HP Scalable NAS should identify the Remote Management
Controller associated with each server. Use the appropriate option for your site
(--hostname, --hostsuffix, or --ipdelta).
[--bladeslot <slot>]
For IBM BladeCenter only, the blade slot.
--hostname <host name>
The hostname for the Remote Management Controller associated with this server.
You will need to use this method if your Remote Management Controllers are
from different vendors. This method must also be used for IBM BladeCenter
servers.
HP Scalable NAS File Serving Software command reference guide 97