3.6.1 HP PolyServe Matrix Server Event Notification Guide (T5392-96028, August 2008)
Table Of Contents

Chapter 3: Event Messages 27
4618 Probe failed: <IP address> Socket connection has timed out after <number>
seconds.
The monitor probe failed on the specified server. The server may no longer
be suitable for the virtual host associated with the monitor. If the virtual host
was active on the affected server, it may have failed over to another server.
(Whether failover occurs is dependent on the configuration of the monitor
and the virtual host.)
Action. Verify that the monitor is configured correctly. Check the server and
the network interface associated with the virtual host for problems.
4619 Socket timeout resolved.
Action. None. Alert 4618 is resolved.
4620 Probe failed: <IP address> Socket select error: <error>
The monitor probe failed on the specified server. The server may no longer
be suitable for the virtual host associated with the monitor. If the virtual host
was active on the affected server, it may have failed over to another server.
(Whether failover occurs is dependent on the configuration of the monitor
and the virtual host.)
Action. Verify that the monitor is configured correctly. Check the server and
the network interface associated with the virtual host for problems.
4621 Socket select error resolved.
Action. None. Alert 4620 is resolved.
4622 Probe failed: <IP address> A domain to resolve must be supplied.
The monitor probe failed on the specified server. The server may no longer
be suitable for the virtual host associated with the monitor. If the virtual host
was active on the affected server, it may have failed over to another server.
(Whether failover occurs is dependent on the configuration of the monitor
and the virtual host.)
Action. Verify that the monitor is configured correctly. Check the server and
the network interface associated with the virtual host for problems.
4623 A domain to resolve supplied.
Action. None. Alert 4622 is resolved.
ID Message and Corrective Action