3.6.1 HP PolyServe Matrix Server Event Notification Guide (T5392-96028, August 2008)

Chapter 3: Event Messages 19
4570 Probe failed: <IP address> SNMP Get request failed.
The monitor probe failed on the specified server. The server may no longer
be suitable for the virtual host associated with the monitor. If the virtual host
was active on the affected server, it may have failed over to another server.
(Whether failover occurs is dependent on the configuration of the monitor
and the virtual host.)
Action. Verify that the monitor is configured correctly. Check the server and
the network interface associated with the virtual host for problems.
4571 SNMP Get request error is resolved.
Action. None. Alert 4570 is resolved.
4572 Probe failed: <IP address> SNMP Get request timed out.
The monitor probe failed on the specified server. The server may no longer
be suitable for the virtual host associated with the monitor. If the virtual host
was active on the affected server, it may have failed over to another server.
(Whether failover occurs is dependent on the configuration of the monitor
and the virtual host.)
Action. Verify that the monitor is configured correctly. Check the server and
the network interface associated with the virtual host for problems.
4573 SNMP Get request timeout is resolved.
Action. None. Alert 4572 is resolved.
4574 Probe failed: <monitor> Filesystem could not be opened.
The monitor probe failed on the specified server. The server may no longer
be suitable for the virtual host(s) associated with the monitor. If the virtual
host(s) were active on the affected server, they may have failed over to
another server. (Whether failover occurs is dependent on the configuration
of the monitor and the virtual host(s).)
Action. Verify that the monitor is configured correctly. Check the server and
the network interface associated with the virtual host(s) for problems.
4575 Filesystem open error resolved.
Action. None. Alert 4574 is resolved.
ID Message and Corrective Action