Online Insertion of New Storage
Matrix Server supports online insertion (OLI) of new storage, provided
that OLI support is present for your combination of storage device, SAN
fabric, HBA vendor-supplied device driver, and the associated HBA
vendor-supplied libhbaapi. (Check with your vendors to determine
whether OLI is supported.)
NOTE: OLI of new storage can cause an interruption of normal
operations on your storage device. Because of this, it is
recommended that OLI of new storage be scheduled for off-peak
hours.
When the appropriate lower-level OLI support is in place, inserting a new
disk will cause a new device to automatically become eligible for
importing. The disk can be imported with the Management Console or
mx utility, and can be used normally from that point forward.
If OLI is not possible with your hardware combination, you will need to
reboot the servers after inserting a new disk. The disk will then be visible
to the matrix.
Online Replacement of a FibreChannel
Switch
This procedure applies only to sites using EMC PowerPath.
When a matrix includes multiple FibreChannel switches, you can replace
a switch without affecting normal matrix operations. The following
conditions must be met when performing online replacement of a
FibreChannel switch.
The replacement switch must be the same model as the original switch
and must have the same number of ports.
The FC connectors must be reinserted in the same location on the new
switch. For example, the FC connector that was plugged into port 1 on
the original switch must be plugged into port 1 on the new switch.
Matrix Server must be stopped on any servers that are connected only
to the switch to be replaced.