3.4.0 Matrix Server Installation Guide
Chapter 2: Install PolyServe Matrix Server 11
Copyright © 1999-2007 PolyServe, Inc. All rights reserved.
6. Install Emulex HBA API Libraries
This step is needed only if your servers use Emulex HBAs.
The HBA API libraries are provided with the HBAnyware package,
which is included in the HBA driver download. To ensure that the correct
libraries are available for Matrix Server, you will need to install the
HBAnyware package on each server that will be in the matrix.
7. Configure the Storage Array
Perform the initial configuration of the storage array as described in the
product documentation. If you will be using the XIOtech
MAGNITUDE
storage array, see the PolyServe Knowledge Base article “Configure the
XIOtech MAGNITUDE Array” for more information.
8. Install the iSCSI Initiator (iSCSI Configurations
Only)
Install the Microsoft iSCSI Initiator on each server according to the
product documentation.
9. Install Third-Party MPIO Software (Optional)
If you will be using third-party MPIO software, install it according to the
product documentation. Also check MatrixLink, on the PolyServe Web
site, for additional information.
10. Configure FC Switches (FC Fabric
Configurations Only)
When certain problems occur on a server (for example, hardware
problems or the loss of matrix network communications), and the server
ceases to effectively coordinate and communicate with other servers in
the matrix, Matrix Server must remove the server’s access to filesystems
to preserve data integrity. This step is called fencing.