3.4.0 Matrix Server Administration Guide

Appendix B: Error and Event Log Messages 236
Copyright © 1999-2006 PolyServe, Inc. All rights reserved.
Network error -- set_readable called with unknown socket N
Network error -- set_writeable called with unknown socket N
If you receive this message, notify PolyServe Technical Support at your
earliest convenience.
Object not found -- could not find service monitor
instance: IP X.X.X.X port N
The ClusterPulse process received a status message from the
monitor_agent process regarding the service monitor for virtual host
address IP X.X.X.X on port N, but the process does not recognize the
service monitor. Probably the Management Console has removed the
service monitor and monitor_agent has already sent the status to
ClusterPulse. Therefore, no corrective action is required.
Script error -- Internal consistency error in
Matrix Server daemon: wrong parameters
If you receive this message, notify PolyServe Technical Support at your
earliest convenience.
Script error -- max pipe write retry attempt limit for
monitor agent monitor_agent. Shutting down agent.
Script error -- socket write error for agent monitor_agent.
Shutting down agent.
Script error -- Write to monitor failed: <errorno
description> for agent monitor_agent. Shutting down agent.
Script error -- Write to monitor failed: <errorno
description>. This probably means the agent has crashed for
agent monitor_agent. Shutting down agent.
The ClusterPulse process experienced an error while trying to write to the
monitor_agent process. It will attempt to recover from this failure.