3.4.0 Matrix Server Administration Guide
Appendix B: Error and Event Log Messages 234
Copyright © 1999-2006 PolyServe, Inc. All rights reserved.
ClusterPulse Messages
Bad command -- Could not find device monitor instance for XXX
on server YYY
The monitor_agent process is reporting status on a device monitor with
device name XXX on server YYY but the ClusterPulse process does not
recognize this device. Probably the Management Console has removed
the device monitor and monitor_agent has already sent the status to
ClusterPulse. Therefore, no corrective action is required.
Bad command -- Matrix Server process received an
unknown action or context reply from the agent monitor_agent:
[STATUS, EVENT,UNDEF] [SERVICE, DEVICE, UNKNOWN]
The message from the agent was not interpreted. This may indicate that
the versions of the monitor_agent and ClusterPulse processes are not the
same.
Configuration error -- could not write to configuration file
The ClusterPulse process was unable to write to the specified
configuration file. The text following the error message provides more
information about the problem. For example, it may state that a
filesystem is full.
Connection error -- send failed: N
Connection error -- transmit failed, no connection to
destination
Connection error -- total send failure
The ClusterPulse process experienced communication errors while trying
to send status to the PolyServe Management Console or an mx command.
The connection to the UI process needs to be re-established.
Internal system error -- Internal error at server X.X.X.X:
select returned with an unknown read socket N
Internal system error -- Internal error at server X.X.X.X:
select returned with an unknown write socket N