When a failure occurs on the Primary, the virtual host needs to fail over to
a backup. Matrix Server now looks for the best location for the virtual
host. Because the probe status on the first backup is “down,” Matrix
Server chooses the second backup, where the probe status is “up.”
At i5 in the following example, the probe fails on the Primary. At i6, the
virtual host is deconfigured on the Primary. At i7, the monitor stop script
begins on the Primary. At i8, the virtual host is configured on the second
backup. At i9, the monitor start script begins on the second backup. At
i10, probing begins on the second backup.