3.1.2 MxFS-Linux Administration Guide

Chapter 2: Configure Export Groups 22
Copyright © 1999-2006 PolyServe, Inc. All rights reserved.
cannot find the export path. A deleted export path should be either
recreated or removed from the Export Group at the administrators
earliest convenience.
Advanced Options for Export Groups
The advanced options allow you to tailor the configuration of the
high-availability monitor associated with an Export Group.
Probe Configuration
The Probe Configuration tab can be used to configure the timeout and
frequency for the probe initiated by the high-availability monitor.
Timeout: The maximum amount of time that MxFS will wait for a probe
to complete. The default is 15 seconds. This value should be adequate for
most environments. However, if nsfd is extremely busy (as in HPC
environments), you may need to increase the timeout to prevent false