3.1.2 Matrix Server SLES9 Release Notes
PolyServe Matrix Server Release Notes 20
Copyright © 1999-2006 PolyServe, Inc. All rights reserved.
12778 Emulex LUN discovery is not optimal
For Emulex adapters, ensure that LUNs are being discovered by
the operating system when the FC driver loads. System files
such as /proc/scsi/device_info may need to be configured for your
storage.
13594 Matrix Server requires that local passwd and group files be
used
Matrix Server requires that the pmxs user and group be present
in the local /etc/passwd and /etc/group files. The system must be
configured to use these files to avoid dependence on external
services that might affect high availability.
14027 mx fs destroy partially destroys snapshots
Do not use the mx fs destroy command to remove a snapshot. If
you attempt to delete a snapshot with the mx fs destroy
command, the snapshot filesystem will be removed but the
snapshot will remain on the array. You will then need to
manually remove the snapshot LUNs from the array. (After
removing the LUNs, you will see disk import errors on the
console for the LUNs that were removed.)
If you need to delete a snapshot, either use the mx snapshot
destroy command or locate the snapshot on the PolyServe
Management Console, right-click, and select Delete.
Defect
Description