3.1.2 Matrix Server SLES9 Release Notes

PolyServe Matrix Server Release Notes 13
Copyright © 1999-2006 PolyServe, Inc. All rights reserved.
1717 Management Console does not display persistent mounts
Certain error conditions can cause a server to lose access to a
PSFS filesystem. When you unmount the evicted filesystem, the
Management Console no longer displays persistent mount
information for that filesystem. You will need to log out of the
Management Console and then log back in to see the
information.
1735 Matrix Server does not shut down applications
When Matrix Server is shut down, it terminates processes that
have open files on PSFS filesystems. To avoid this problem, we
recommend that you stop applications that are using the
filesystem before you shut down Matrix Server.
7250 Failover can take too long
When the IBM RDAC software is being used, the time required
for failover is dependent on the RDAC software. If failover
times are too long, consult the RDAC PAL on MatrixLink for
tuning suggestions.
7519 Third-party MPIO software must discover devices
When third-party MPIO software such as EMC PowerPath or
IBM RDAC is used, the third-party MPIO software must
discover and present storage devices to the operating system
before Matrix Server is configured or started.
If Matrix Server is started and the third-party MPIO software
has not previously discovered the devices, Matrix Server will
make a “best effort” to discover them. In some cases, Matrix
Server will initiate a single reboot. Matrix Server will not start if
it cannot discover the devices. The administrator must then
determine why the MPIO devices have not been discovered and
resolve the issue.
Defect
Description