3.1.2 Matrix Server Administration Guide
Appendix B: Error and Log File Messages 280
Copyright © 1999-2006 PolyServe, Inc. All rights reserved.
panpulse will not provide service until the required
interface flags (UP, RUNNING, BROADCAST, MULTICAST) are set
on interface <ethn>. See ifconfig(8).
IPv4
Only IPv4 is supported. If another address family is specified for the
network, PanPulse will report an error such as the following:
Interface <ethn> has addrtype AF_INET6, skipping
Separate Networks
Each network interface card must be on a separate network. If this is not
the case, PanPulse will report the following error:
Interface <ethn> will not be used by panpulse because it
exists on the same network as interface <ethn>. This
configuration is not supported by PolyServe Matrix Server.
Port 8940
Only one instance of PanPulse can be running on port 8940 on a server. If
another application is using that port or another instance of PanPulse is
started, the following error will be reported.
Unable to bind on port 8940. Please make sure that this is
the only copy of panpulse running on this server.
mxinit Messages
mxinit prints a series of messages when it cannot complete an operation.
For example, mxinit must unmount all PSFS filesystems before it shuts
down Matrix Server. If a filesystem is busy, it cannot be unmounted.
mxinit will then issue a message about the filesystem, followed by
additional messages stating that mxinit could not complete the various
steps involved in shutting down Matrix Server.
Similarly, if mxinit cannot start Matrix Server because, for example, the
system is out of resources, you will see a series of messages reporting that
start-up actions could not be completed.