3.1.2 Matrix Server Administration Guide

Appendix B: Error and Log File Messages 275
Copyright © 1999-2006 PolyServe, Inc. All rights reserved.
Monitor error -- monitor_agent reported N:: <error string>
The monitor_agent daemon experienced an error and is copying the
error string to the matrix.log file. Inspect the error string for details about
resolving the error.
Network error -- set_readable called with unknown socket N
Network error -- set_writeable called with unknown socket N
If you receive this message, notify PolyServe Technical Support at your
earliest convenience.
Object not found -- could not find service monitor
instance: IP X.X.X.X port N
The ClusterPulse daemon received a status message from the
monitor_agent daemon regarding the service monitor for virtual host
address IP X.X.X.X on port N, but the daemon does not recognize the
service monitor. Probably the Management Console has removed the
service monitor and monitor_agent has already sent the status to
ClusterPulse. Therefore, no corrective action is required.
Read error - could not read configuration file
The ClusterPulse daemon experienced an error when reading from the
specified configuration file /etc/opt/polyserve/cp_conf. Verify that root has
read access to the file.
Script error -- Internal consistency error in Matrix Server
daemon: wrong parameters
If you receive this message, notify PolyServe Technical Support at your
earliest convenience.
Script error -- max pipe write retry attempt limit for
monitor agent monitor_agent. Shutting down agent.
Script error -- socket write error for agent monitor_agent.
Shutting down agent.