HP StorageWorks 700ux/1100ux Optical Jukebox Service Manual (AA962-96004, September 2004)
Service Preparation
39700ux/1100ux Optical Jukebox Service Manual
Replacing the jukebox
1. Power off the jukebox to be replaced.
2. If the jukebox is in a rack, remove it from the rack. Refer to the HP StorageWorks
700ux/1100ux Optical Rack Mount Installation poster, part number AD505-96001, for
more information.
3. Remove the two T-10 Torx screws that secure the top panel to the jukebox and lift the top
panel off the jukebox (see Figure 2).
4. Remove the drive(s) from the jukebox to be replaced (the rails do not need to be removed
from the drive(s)):
a. Remove the two T-10 Torx screws that secure the drive’s rails to the jukebox frame
(see Figure 4) on either side of the drive.
b. Slide the drive two inches toward the front of the jukebox, so that you have room to
disconnect the cables from the drive.
c. Disconnect the cables from the drive.
d. Slide the drive out of the jukebox.
5. Note the slot positions of the cartridges, then remove all of the cartridges from the
jukebox.
6. Remove the configuration module (if present) from the jukebox (see Installing or
replacing the slot configuration module, page 37).
7. Power on the jukebox to be replaced.
8. Run the SHIPPING PARK test to put the picker into shipping position:
a. From the OCP displaying READY, press the NEXT button until you see ADMIN, then
press ENTER.
b. Use the PREV and NEXT buttons to enter the password (default is 000 000 000), then
press ENTER.
c. At the TEST menu, use the PREV and NEXT buttons to select SHIPPING PARK, then
press ENTER.