HP StorageWorks 700ux/1100ux Optical Jukebox Service Manual (AA962-96004, September 2004)

Troubleshooting and Diagnostics
17700ux/1100ux Optical Jukebox Service Manual
Administration
Forgot the password
Enter the default password (000
000 000).
Clear the password (requires
minimum firmware level 5.01).
1. If necessary, press CANCEL to get
to the READY mode.
2. Hold down the ENTER button and
press PREV and NEXT so that all
three are pressed at the same
time.
3. When <<MAINTENANCE>>
PASSWORD>> displays, release
the buttons.
4. Press ENTER, ENTER, NEXT.
5. Press NEXT or PREV to go to
menu item 41: PASSWORD
RESET, then press ENTER.
6. Press PREV, NEXT, ENTER.
7. P re s s CANCEL until ON LINE
MODE? displays.
8. Press ENTER.
You want to stop a test that is running Press CANCEL. The current test loop
continues until finished, then the test
stops.
Table 2: Troubleshooting installation (Continued)
Problem Solution