HP StorageWorks 700ux/1100ux Optical Jukebox Service Manual (AA962-96004, September 2004)

Troubleshooting and Diagnostics
13700ux/1100ux Optical Jukebox Service Manual
The power-on selftest failed and
DEVICE FAILED is displayed
Ensure the two shipping screws on
the left side of the jukebox have
been removed.
Power cycle the jukebox.
Check for proper cable connections
to the drive(s).
If the power-on test continues to fail,
write down the displayed error code
and a micro move error, then
remove the top cover and check for
cartridges that are out of position or
other obstacles.
Power to the jukebox failed while a disk
was in the drive and the display did not
return to
READY after the power came
back on
Power cycle the jukebox.
If READY does not display
(power-on test is unsuccessful), write
down any error messages, then
remove the top cover and check for
cartridges that are out of position or
other obstacles.
Check for proper cable connections
to the drive(s).
Caution: Do not move the unit!
Moving the unit risks damaging
the optical drive.
Other SCSI devices no longer work
when the jukebox is installed
Check SCSI ID assignments and
resolve any conflicts.
Ensure that the SCSI ID for the HBA
is different from that of the jukebox.
Check for proper SCSI cabling and
termination.
Ensure the maximum cable length
for the bus has not been exceeded
(12 meters for LVDS and 3 meters
for SE).
Table 2: Troubleshooting installation (Continued)
Problem Solution