HP StorageWorks 1000ux/1900ux/2300ux Optical Jukebox Setup Guide (AA966-96002, September 2004)

Unpacking
13HP StorageWorks 1000ux/1900ux/2300ux Optical Jukebox Setup Guide
Table 2: Location criteria
Specification Description
Clearance Enough room to comfortably insert disks
in the mailslot with 2-3 inches on all
other sides to allow air circulation.
Power requirements
Line voltage: 100 to 240 VAC
Line frequency: 50 to 60 Hz
Power consumption:
275 W maximum
Temperature:
Operating temperature
Non-operating temperature (without
media)
10ºC to 35ºC (50ºF to 95ºF)
-40ºC to 60ºC (-40ºF to 140ºF)
Humidity:
Operating humidity
Non-operating humidity (without
media)
10% to 80% RH
5% to 90% RH
Light Avoid very bright or concentrated light
as it can interfere with the optical
sensors.
Air quality
Caution: Excessive dust and
debris can damage optical
media and drives.
Minimal sources of particulate
contamination. Avoid areas near
frequently used doors and walkways,
stacks of supplies that collect dust,
printers that create paper dust, and
smoke-filled rooms.