HP StorageWorks 2000 Modular Smart Array G2 cable configuration guide (457746-004, June 2009)

MSA2000sa G2 switch-connect configurations
IMPORTANT:
Any number or combination of LUNs can be shared among
a maximum of 32 single-density blade servers or 16 dual-
density blade servers as long as the total adds up to no more
than 512 LUNs per MSA2000sa G2.
NOTE:
A volume cannot be mapped to LUN 0.
Single density configurations support two 3Gb SAS BL Switches
per blade enclosure.
Dual density configurations support four 3Gb SAS BL Switches
per blade enclosure.
Only use supported mini-SAS 4x cables with 3Gb connectors.
Blade enclosures — blade servers/two 3Gb SAS BL
switches
Cables required: eight (8) mini-SAS 4x cables.
MSA2000sa expansion configurations
Connecting to an MSA2000 3.5” 12–drive enclosure
A: Connecting an MSA2000sa G2 single-controller array enclosure to
an MSA2000 3.5” 12–drive enclosure with a single I/O module requires
one (1) mini-SAS to SAS cable.
A + B: Connecting an MSA2000sa G2 dual-controller array enclosure
to an MSA2000 3.5” 12–drive enclosure with dual I/O modules requires
two (2) mini-SAS to SAS cables.
Page 5