HP Direct-Connect External SAS Storage for HP BladeSystem Solutions Depoyment Guide
MDS600 and MSA2000 G2 to the same c-Class enclosure
This example illustrates cabling from one BladeSystem c-Class enclosure to both an MSA2000sa
G2 controller enclosure
and
an MDS600 storage enclosure. In this type of configuration, note the
following:
IMPORTANT:
• In a solution with both zoned and shared storage enclosures, a server bay can be assigned
to either zoned or shared zone groups. (Cannot be assigned to both types of storage
enclosures.)
• The MSA2012sa is not supported for use in this configuration.
Devices and quantities
MSA2300sa controller enclosures: 1
MSA2000 drive enclosures: 3
MDS600 storage enclosures: 1
c7000 enclosures: 1
3Gb SAS BL Switches: 2
Server blade types: half-height and full-height
Connection details
• Switch in interconnect bay 5:
◦ Port 1: to MSA G2 SAS port A1
◦ Port 2: to MSA G2 SAS port B1
◦ Port 3: to MDS600 drawer 2, primary
I/O module, port 1
◦ Port 4: to MDS600 drawer 2, primary
I/O module, port 2
◦ Port 7: to MSA2000sa drawer 1,
primary I/O module, port 1
◦ Port 8: to MDS600 drawer 1, primary
I/O module, port 2
• Switch in interconnect bay 6:
◦ Port 1: to MSA G2 SAS port A1
◦ Port 2: to MSA G2 SAS port B1
◦ Port 3: to MDS600 drawer 2,
secondary I/O module, port 1
◦ Port 4: to MDS600 drawer 2,
secondary I/O module, port 2
◦ Port 7: to MSA2000sa drawer 1,
secondary I/O module, port 1
◦ Port 8: to MDS600 drawer 1,
secondary I/O module, port 2
MDS600 and MSA2000 G2 to the same c-Class enclosure 113