IMPORTANT - HP StorageWorks 1500 Modular Smart Array: Announcing active/active support (405626-023, November 2006)
3
To upgrade already-installed MSA1500 and
this new MSA1500 to active/active:
When adding this new MSA1500 to a SAN with existing active/passive
MSA1500 and/or other array controllers, first migrate all existing servers and
MSA1500 to active/active, and then install and upgrade this new MSA1500.
1. Go to the MSA1500 website: http://www.hp.com/go/msa1500cs.
2. From the Software, firmware & drivers page, obtain the following:
• active/active version Support Software CD ISO image (burn the ISO image
to a blank CD)
• active/active version controller firmware files or ISO image
• release notes for the Support Software CD and the firmware files
3. From the Technical documents page, obtain the following:
• Migration instructions for your operating system (Windows, Linux, and HP-UX
only; OpenVMS and Tru64 UNIX are newly supported operating systems, so
there are no already-installed MSA1500 to migrate.)
• Installation guide (October 2006 or later)
• Firmware updating guide
4. Upgrade any existing MSA from active/passive to active/active as described in
the migration instructions, including:
• Complete all prerequisites.
• Upgrade the servers and any existing active/passive MSA to active/active.
5. Install and configure the new MSA as described in the installation guide.
When instructed:
• Install MSA components on the servers using the Support Software CD
created in step 2.
• Upgrade the firmware on the MSA using the files obtained in step 2 and the
firmware updating guide obtained in step 3.
To use the pre-installed active/passive
firmware:
1. Locate the following documents, shipped with the MSA:
•Configuration overview poster
• Installation guide
2. Install and configure the MSA as described in the installation documents.
When instructed, upgrade to the latest version of active/passive firmware. Do