HP StorageWorks 1500 Modular Smart Array maintenance and service guide (356606-002, October 2006)

2
1
15521
Installing
the component
Slide the re
placement fan module into the MSA chassis bay until the module clicks into place.
15522
Verifying proper operation
After replacing the fan module, verify that:
The fan starts operating immediately.
The fan Status LED is On.
No new error messages are displayed on the array controller LCD panel.
Replacing a SCSI I/O module
Before you begin
CAUTION:
Before removing a component or blanking panel from an operational device, make sure that you
have the replacement part available. Removing a component or blank impacts the airow and
cooling ability of the device. To avoid possible overheating, insert the new or replacement component
within one or two minutes. If the internal temperature exceeds acceptable limits, the device may
overheat and automatically shut down or restart.
Parts can be damaged by electrostatic discharge. Use proper anti-static protection.
maintenance and service guide
89