HP StorageWorks 1500 Modular Smart Array maintenance and service guide (356606-002, October 2006)

Installing the controller
1. Insert the new or serviced array controller into the MSA chassis controller bay (1).
2. Push the controller in as far as it will go, making sure that the controller is seated, and then press the
latch handle inward until it is ush against the front panel (2).
1
2
15493
3. If necess
ary, power on the MSA as instructed in Connecting the Power and Applying power to
the MSA.
NOTE:
Each time a system with two controllers is powered on or restarted, or if a second controller is
hot-plug
ged into a single-controller conguration, the rmware versions on the controllers are compared.
If the r
mware versions on the two controllers are not the same, the controller LCD panel prompts to clone
the rmware from the controller with the latest version onto the other controller. For information, see
Cloning controller rmware.
Verifying proper operation
After replacing the array controller, controller cache module, or cache module battery pack, verify that:
The controller Heartbeat LED is blinking.
The controller Fault LED is off.
No new error messages are displayed on the array controller LCD display panel.
After installing a new array controller, verify that the latest available rmware is installed. See Array
controller rmware for the following instructions:
Determining the currently-installed rmware version
Updating controller rmware
Cloning controller rmware
Recovering corrupted rmware
84
Customer replaceable components