HP StorageWorks 1500 Modular Smart Array maintenance and service guide (356606-002, October 2006)

Controller LEDs
During normal r
untime, the array controller has 18 LEDs that indicate controller activity or malfunction.
12 11 10131415161718
7 8 9654321
15588
Item Name
Condition
Meaning
1
Drive failure
On
Aconguredharddrivehasfailed.
On
Cache active.
Off
No cache activity.
2
Cache activity
Blinking
Cache transfer pending.
3
SCSI bus 1 activity
On
Activity on the bus.
4
SCSI bus 0 ac
tivity
On
Activity on
the bus.
5
Logical I/O activity
On
Currently processing logical requests from
the host adapter.
6
Direct Memory Access
(DMA) activity
On
DMA transfers are active.
On
This controller is active.
7
Active/St
andby
Off
This controller is standby.
8
Heartbeat Blinking
The controller is functioning properly.
9
Fault On (amber
)
An error m
essage has been sent to the
controll
er LCD display panel.
10
Redundancy active
On (green)
The two controllers and the two Fibre
Channel I/O modules are in a redundant
mode of operation.
On
The controller is idle.
11–13
Busy status These
three LEDs are used to
progressively represent the
processing load on the
controller.
Off The cont
roller is operating at full capacity.
14–18
Fibre Channel ID
Indicates the 5–bit Arbitrated Loop Physical
Address (ALPA) assigned to this array
contr
oller (not applicable in fabric mode).
maintenance and service guide
23