HP StorageWorks 1500 Modular Smart Array Installation Guide (355901-004, October 2006)
Configuration Procedures - Other Environments
95HP StorageWorks 1500 Modular Smart Array Installation Guide
d. For each HBA, verify that the following options are specified: load
ql2x00.ham slot=x/luns/allpaths/portnames, where x
represents the slot number.
Note: The Native MPIO solution can co-exist with HP Secure Path for NetWare.
■ If the MSA is upgraded to 6.86or later active/active firmware, and, if you want
to remove the Secure Path for NetWare driver, do the following:
a. Follow the removal instructions provided in the Secure Path user
documents.
b. From the console, enter edit c:\NWSERVER\STARTUP.NCF.
c. Comment out the following entry: #load hpqsp.cdm
d. Enter edit sys:\system\autoexec.ncf
e. Comment out the following entries:
Tru64 UNIX environments
■ Single-controller configurations and active/passive firmware are not
supported; the MSA must be upgraded to dual-controllers running
active/active firmware.
■ The AlphaServer must have Tru64 UNIX v5.1.b PK4 (or later) installed.
■ The AlphaServer must be configured in a SAN switch zone with the MSA.
■ After installing the MSA, be sure to set the host mode for each Tru64 UNIX
connection to tru64.
■ For information on upgrading the MSA to active/active, see the migration
instructions for Tru64 UNIX environments, available on the Technical
documents page of the MSA1500 website:
http://www.hp.com/go/msa1500c s
.
LOAD hpqspagt.nlm
LOAD hpqspahw.nlm