HP StorageWorks 1500 Modular Smart Array Installation Guide (355901-004, October 2006)

Configuration Procedures - HP-UX Environments
83HP StorageWorks 1500 Modular Smart Array Installation Guide
Direct connect configuration notes:
For direct connect configurations you must enable FC-AL hard
addressing on the MSA controller. See the ACU or CLI online help or
user documentation for instructions.
LUN configuration notes:
In direct connect environments or in any environment when using the
ACU-CLI, a minimum of one storage LUN on the MSA must be
configured and set to the HP-UX host mode before connecting the MSA
to the HP-UX server.
HP-UX version Required update for active/active
11.11 systems HWE0509 Online Diagnostics Support Tools
Bundle, Sept. 2005 (or later)
11.23 systems HWE0603 Online Diagnostics Support Tools
Bundle, June 2006 (or later)
These bundles are available on the HP Software Depot home website:
http://h20293.www2.hp.com
. Click Enhancement releases and
patch bundles, navigate to Diagnostic and Support Tools for the HP
9000, Integrity Servers, and Intel Itanium 2 Workstations, and then
click Receive for Free. Then, follow the onscreen instructions to
obtain the bundle.