HP StorageWorks 1500 Modular Smart Array Installation Guide (355901-004, October 2006)
Installation Procedures - All Deployments
35HP StorageWorks 1500 Modular Smart Array Installation Guide
Table 4: MSA1500 specifications
Parameter Value
Dimensions:
Height
Width
Depth
3.46 in (8.79 cm)
24.0 in (60.96 cm)
17.64 i n (4 4.81 c m)
Weight
Shipping configuration 41.6 lb (18.9 kg)
Input Power:
Rated Input Voltage
Rated Input Frequency
Maximum Rated Input Current
Maximum Input Power
100 to 240 VAC
47-63 Hz
1. 3 A
160 W*
Heat Dissipation (max) 2187 Btu/hr*
Temperature Ranges:
Operating temperature
Shipping temperature
50° F to 95° F (10° C to 35° C)
[derated 1.8° F (1° C) per 1000 ft
(304.8 m) of elevation to 10,000 ft
(3048 m)]
-22° F to 122° F (-30° C to 50° C)
Relative Humidity (non-condensing):
Operating
Non-operating
10% to 90%
up to 95%
Maximum Wet bulb Temperatures:
Long term storage
Short term storage
84.2° F (29° C)
86° F (30° C)
*Input power and heat dissipation specifications are maximum values and apply to
worst-case conditions at full-rated power supply load. The power/heat dissipation
for your installation varies depending on the equipment configuration.