HP StorageWorks Storage Mirroring Recover Scripting Guide (T5437-96022, November 2010)

ExtensionNumber
Description—Used by the Storage Mirroring Recover log files.
FailbackHostname
Description—Returns the host SPN (Service Principle Name) to its
original setting on failback
Values—0 Disabled, 1 Enabled
Default—0
GUI Setting—Failover Control Center, Monitor Settings, Active Directory,
Failback Hostname
Service restart required—No
Notes—If you are using Active Directory, this option should be enabled or
you may experience problems with failback.
FailoverHostname
Description—Automatically removes the host SPN (Service Principle
Name) from Active Directory on the source
Values—0 Disabled, 1 Enabled
Default—0
GUI Setting—Failover Control Center, Monitor Settings, Active Directory,
Failover Hostname
Service restart required—No
Notes—If you are using Active Directory, this option should be enabled or
you may experience problems with failover.
FailoverOnRouteFailure
Description—Determines if failover will occur when receiving a router
message back from an IP address on the network
Values—0 Failover will not occur when receiving a destination host
unreachable message, 1 Failover will occur when receiving a destination
host unreachable message
Default—1
GUI Setting—None
Service restart required—No
FCCHelpPath
Description—This entry is no longer used.