Brocade FICON Administrator's Guide v7.1.0 (53-1002753-01, March 2013)

FICON Administrator’s Guide 13
53-1002753-01
FICON commands
1
For limitations and considerations for using Fabric OS commands with FMS mode enabled, refer to
“Fabric OS command limitations and considerations” on page 40.
ficonclear rnid Removes all outdated RNID records from the local RNID
database.
ficoncfg
--set LIRR <portnumber> Sets the current LIRR device port number persistently.
ficoncfg
--reset LIRR <portnumber> Clears the currently configured LIRR port number.
ficonhelp Displays a list of FICON support commands.
ficoncupset fmsmode enable|disable Enables or disables FICON Management Server (FMS) mode.
ficoncupset modereg <bitname> 0|1 Sets FICON-CUP mode register bits.
ficoncupset MIHPTO <seconds> Sets missing interrupt primary timeout (MIHPTO) values.
ficoncupset CRP <PID> <CHID> Sets the current reporting path (CRP).
ficoncupshow DD_LOG Displays the log information associated with the last diagnostic
command processed by the CUP.
ficoncupshow diag_info Displays the diagnostic interval setting and related statistic
sampling information for diagnostic information collected by the
CUP.
ficoncupshow fmsmode Displays the current FMS mode setting.
ficoncupshow hlthchk_log Displays health check logs for the logical switch.
ficoncupshow modereg <bitname> Displays FICON-CUP mode register bits.
ficoncupshow MIHPTO Displays MIHPTO values.
ficoncupshow LP Displays the CUP logical path and error reporting path
information.
ficonshow lirr [fabric] Displays registered listeners for link incidents for the local switch
or for the fabric, if specified.
ficonshow rlir [fabric] While all FICON channels register as “conditional” recipients of
registered link incident reports (RLIRs) and are added to the
switch LIRR database, only one channel per switch is selected to
forward reports to the host. The command output displays all
channels which have registered and indicates which node on
each switch is selected to generate reports to the host.
ficonshow rnid [fabric] Displays node identification data for all devices registered with
the local switch or all devices registered with all switches defined
in the fabric, if specified.
ficonshow rnid [port] Displays node identification data for a specified port.
ficonshow switchrnid [fabric] Displays node identification data for the local switch or for the
fabric, if specified.
TABLE 1 Fabric OS commands related to FICON (Continued)
Command Description