Brocade FICON Administrator's Guide v7.1.0 (53-1002753-01, March 2013)
FICON Administrator’s Guide 83
53-1002753-01
Supported Brocade blades
A
Unsupported blades
The following port blades are not supported in a FICON environment:
• FCOE10-24
• FS8-18
• FC4-48
• FC8-32E
• FC8-48E
1. The IP ports of an FX8-24 extension blade can operate with another FX8-24 or 7800. The maximum number of FX8-24 blades
supported in a chassis it four. An FX8-24 can operate with an FX8-24E; however, IPSEC and compression is only supported on
one 10G IP port on the FX8-24.
2. The 64 port card is not supported for FICON but may be in the same chassis used for FICON. It must be in a logical switch that
does not have any FICON traffic.
3. For the 48 port card in an 8-slot chassis, FICON is supported in a logical switch configured for zero-based addressing mode.
For this card in a DCX-4S backbone, FICON is supported only on a logical switch defined for port-based (mode 2) addressing.
4. FC10-6 10Gbps port blade for ISL connections.