88 FICON Administrator’s Guide
53-1002753-01
Basic Switch Configuration
B
Parameters in Table 12 are only required when 2-byte link addressing is used in the IOCP. Normally,
these parameters are not set when single-byte addressing is used.
TABLE 12 Cascading (2-byte addressing) example and commands
Feature Parameter
Add members to the SCC Policy. secPolicyCreate "SCC_POLICY", "wwn;wwn; …"
Or, to add all switches already in the fabric, just
use an '*' for each WWN:
secPolicyCreate "SCC_POLICY", "*"
Save the policy. secpolicysave
Activate the policy. secpolicyactivate
Enable the ACL Fabric Wide Consistency Policy
and enforce a strict SCC policy.
fddcfg --fabwideset "SCC:S;"